1. Comply with AMS-2750 standard (USA aerospace standard)

2. Able to control precise temperature distribution

3. Complete after-sales support

Add to cart

Product Description

Feature :

1. Comply with AMS-2750 standard (USA aerospace standard)

Jo Kang's car-bottom type annealing furnace able to comply with international standards, such as AMS-2750 – A1, A2 class and CQI-9. To cooperate with customers to reach equipment certification requirements.

2. Able to control precise temperature distribution

The furnace uses advanced refractory materials to optimize the heat preservation effect. Cooperates with the forced convection of the circulating fan to make the internal average temperature reach ±3℃/±5℃. Providing customers, the highest certification standards.

3. Complete after-sales support

Provide customers with complete after-sales services, including shipment, installation, trial operation on site, operator education and training support. Additionally, provided operating and maintenance manual with electric control circuit diagram.

Specification :

Model JK-ALT0-361718
Inside Space L3600×W1700×H1870
Heating Electric / Gas(LPG/LNG)
Temperature Control Programmable temperature control, combined with forced convection of circulating fan.
Temperature Difference ±3℃/±5℃
Maximum Temperature 450℃/550℃
Power 280KW
Applications: Aluminum alloy to annealing heat treatment, steel tempering.

*Able to tailor make by customer's request.

Equipment Specifications :

  • The outside of the furnace is made of steel plate and angle steel, combined with channel steel. The interior of the furnace is made of stainless-steel plates, angle steel and steel rails.
  • The insulation layer in the furnace is made by heat-resistant insulation materials such as insulating rockwool and bulk ceramic fiber.
  • Equipped with a hot air circulation device, using special fan group with a vertical motor to quickly achieve uniform temperature in the furnace.
  • Using Japanese-made programmable thermostat, with PID automatic calculation function, and cooperate with SCR voltage regulator for precise temperature control.
  • When the temperature is abnormal, the independent temperature controller will automatically shut down. Then changed to ON/OFF control for over-temperature protection. Until the processing is completed and a fault signal is issued.
  • Japanese-made electronic/paper-type six-point temperature recorder is used to record the changes in the heat treatment process, which can be used for remote monitoring with communication. Assist to refer and improve the treatment conditions. At the same time, monitor the temperature changes in the treatment process.